Skip to main content

Table 5 The prediction model of pure-tone threshold (PTT) at 0.5, 1, 2, and 4 kHz

From: Prediction of pure tone thresholds using the speech reception threshold and age in elderly individuals with hearing loss

Predicted PTT

Resultant multiple regression model

Adjusted-R2

Prediction model

Adjusted-R2

0.5 kHz

4.04 + 0.91(SRT) − 0.05(age) − 1.18(tinnitus) + 1.07(SAH)

0.8225

3.84 + 0.92(SRT) − 0.05(age)

0.8211

1 kHz

4.59 + 0.93(SRT)– 0.00(age)– 1.14(tinnitus)– 1.41(HT)

0.8881

2.89 + 0.94(SRT) − 0.00(age)

0.8852

2 kHz

5.23 + 0.90(SRT) + 0.6(age)– 0.59(tinnitus)– 0.89(HT)

0.7412

4.22 + 0.90(SRT) + 0.06(age)

0.741

4 kHz

18.41 + 0.68(SRT) + 0.15(age)

0.4109

18.41 + 0.68(SRT) + 0.15(age)

0.4109