Table 3 Summary of dose-volume constraints for the liver

From: Stereotactic Body radiation therapy for liver tumors with or without rotational intensity modulated radiation therapy

Reference Dose-volume Dose-volume
Constraints reported Constraints converted to V(Gy)
Herfarth et al.[10] 12 Gy to 30% V12 ≤ 30%
7 Gy to 50% V7 ≤ 50%
Shefter et al.[18] 700 cc < 15 Gy V15 ≥ 700 cc
Kavanagh et al.[6]
Hoyer et al.[7] 10 Gy total < 30% V10 < 30%
Mendez Romero et al.[17] D33 < 21 Gy V < 21 ≤ 33%