Skip to main content

Table 3 12 month follow-up

From: Single incision device (TVT Secur) versus retropubic tension-free vaginal tape device (TVT) for the management of stress urinary incontinence in women: a randomized clinical trial

 

TVT secur n = 37

TVT n = 30

Fisher exact test results*

RR (95% CI)*

Pad test (primary Outcome)

  

p = 0.49

0.92

  <1 g

27 (82%)

25 (89%)

 

(0.75 – 1.13)

  ≥1 g

6 (19%)

3 (11%)

  

  Pad test not done

4

2

  

Complications since hospital discharge

  

p = 0.13

0.89

(0.79 – 1.00)

  Additional pelvic procedures

31 (89%)

26 (100%)

  

   No

4 (11%)

0 (0%)

  

   Yes

2

4

  

   Unknown

1 (2%)

0 (0.0%)

  

  Surgery for mesh extrusion

    

Vaginal examination

  

p = 0.27

0.85

  Normal palpation

26 (79%)

24 (92%)

 

(0.69 - 1.05)

  Tape palpable but non-tender

7 (21%)

2 (8%)

  

  Unknown/not done

4

4

  

Bimanual examination

  

p = 0.50

0.94

  Normal

32 (94%)

25 (100%)

 

(0.87 – 1.02)

  Abnormal

2 (6%)

0 (0%)

  

  Unknown/not done

3

5

  
  1. Note: *Tests exclude women did not have test or exam, or whose status is unknown.