Table 1 Mean (±SD) for anthropometric measures and range of motion of the wrists

From: Cyborg beast: a low-cost 3d-printed prosthetic hand for children with upper-limb differences

Measurements

Non-affected

Affected

 

Direct

Photographs

Direct

Photographs

Hand Length (cm)

13.83 ± 2.44

13.44 ± 1.73

4.02 ± 1.07

4.25 ± 1.15

Palm Width (cm)

7.00 ± 1.20

6.91 ± 0.95

4.50 ± 0.90

4.54 ± 0.66

Forearm Length (cm)

18.94 ± 3.88

18.94 ± 4.16

16.29 ± 3.41

16.69 ± 4.09

Forearm Width (cm)

6.23 ± 0.85

6.47 ± 1.12

5.57 ± 0.77

5.54 ± 0.59

Wrist Range of Motion Flexion (°)

76.00 ± 10.27

75.33 ± 11.01

56.44 ± 13.15

59.76 ± 13.95

Wrist Range of Motion Extension (°)

76.44 ± 5.7

76.00 ± 6.96

45.67 ± 33.47

43.56 ± 33.29

  1. The results of the two-way repeated measures ANOVAs showed no significant (p >0.05) mean difference between the anthropometric measures taken directly on the subject’s upper limbs and those taken from photographs. There were no significant two-way interactions for repeated measures ANOVAs performed for hand x fitting procedures. There was a significant main effect for hand (affected versus non-affected), with no significant main effect for fitting procedures (direct versus photographs).