Skip to main content

Table 1 Study characteristics of the Cochrane Eye and Vision Group Reviews (EVGRs)

From: Conclusiveness of the Cochrane Eye and Vision Group Reviews

 

‘‘Conclusive’’ EVGRs (n = 56)

‘‘Inconclusive’’ EVGRs (n = 50)

P

Number of RCTsa

10.7 ± 17.1

3.22 ± 5.57

0.003

Total cumulative number of patients enrolledb,c

984 (439–117,272)

50 (0–12,294)

<0.001

Total cumulative number of eyes studieda,d

1,295 ± 2,240

136.2 ± 287.9

0.015

Percent of EVGRs where further studies are neededa

96 ± 20

84 ± 37

0.042

  1. RCTs randomized controlled trials, EVGRs Eye and Vision Group Reviews.
  2. aMean ± SD.
  3. bMedian (range).
  4. cIn 101 of the EVGRs the total cumulative number of participants could be retrieved, 52 of them were conclusive reviews and 49 of them were inconclusive ones.
  5. dIn 62 of the EVGRs the total cumulative number of eyes studies could be retrieved, 26 of them were conclusive reviews and 36 were inconclusive ones.