Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

Abstract

Background

Infection of cardiac implantable electronic devices is a serious cardiovascular disease and it is associated with a high mortality. Mycobacterium species may rarely cause cardiac implantable electronic devices infection.

Case presentation

We are reporting a case of miliary tuberculosis in an Arab patient with dilated cardiomyopathy and a cardiac resynchronization therapy-defibrillator device that was complicated with infection of his cardiac resynchronization therapy-defibrillator device. To our knowledge, this is the third case in the literature with such a presentation and all patients died during the course of treatment. This underscores the importance of early diagnosis and management. We also performed a literature review of reported cases of cardiac implantable electronic devices infection related to Mycobacterium species.

Conclusions

Cardiac implantable electronic devices infection due to Mycobacterium species is an uncommon but a well-known entity. Early diagnosis and prompt management may result in a better outcome.

Background

Infection of cardiac implantable electronic devices (CIEDs) is a serious cardiovascular disease and it is associated with a high mortality. CIEDs infection may occur as a pocket infection or as infection on the leads with infective endocarditis. Cardiac device-related infective endocarditis (CDR-IE) may occur as a primary infection of the CIED system or as a secondary infection as a result of hematogenous seeding during a bacteremia secondary to a distant infected focus [1].

Mycobacterium tuberculosis (TB) is an infection that primarily affects the lungs, but it can involve any other organs and structures such as the kidney, spine, brain, and rarely the heart. TB disease can be fatal if not treated properly (http://www.cdc.gov).

Tuberculosis endocarditis (TBE) has been reported for many years with involvement of native or prosthetic valves mostly in cases of miliary TB [2]. Mycobacterium species are another uncommon but well-described pathogen in CIED infections [3].

We are reporting a case of miliary TB in an Arab patient with dilated cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device. His condition was complicated with TB meningitis and a CDR-IE with vegetations on the leads. He underwent surgical removal of the CRT-D device and leads and a gram stain of the vegetations was positive for acid-fast bacilli (AFB). We also performed a literature review of reported cases with Mycobacterium species related CIEDs infection.

Case presentation

A 50-year-old male Arab patient with non-ischemic dilated cardiomyopathy, biventricular failure with left ventricular ejection fraction (LVEF) of 20 %, moderate to severe mitral regurgitation and tricuspid regurgitation, left bundle branch block, and non-sustained ventricular tachycardia. Cardiac catheterization did not show any significant coronary artery disease. He underwent a CRT-D device implantation, as he was symptomatic with shortness of breath, New York Heart Association Functional Classification-II. He had no history of diabetes mellitus, hypertension, or dyslipidemia. He was on anti-heart failure medications and was on the heart transplantation list.

He presented to the Emergency Department 8 months after CRT-D device implantation with 2 months’ history of high-grade fever, chills, rigors, and weight loss. There was no history of concomitant respiratory, gastroenterology, cardiovascular, or neurologic localizing symptoms. There was no history of contact with febrile or TB patients. He was seen at another medical center and started on intravenous (IV) vancomycin and gentamicin for possible infective endocarditis involving his CRT-D device leads but with no improvement.

On presentation, he was looking chronically ill but not in acute distress. He was febrile with a temperature of 38.8 °C, but he was hemodynamically stable with a blood pressure of 107/57 mm Hg, and heart rate of 98 beats per minute. Oxygen saturation was 92–94 % on room air. Cardiovascular exam showed a jugular venous pressure (JVP) at 4 cm above the sternal angle; normal first and second heart sounds with a soft systolic murmur at left lower sternal border which was reported in his previous physical exam. The device site in the left upper chest was normal. There was no lower limb edema and no stigmata of infective endocarditis. Chest exam showed bilateral basal crepitations. Neurological exam was unremarkable.

Laboratory tests; CBC showed mild anemia, and thrombocytopenia with normal white blood count. Renal profile was normal and hepatic profile showed mild elevation of aspartate aminotransferase (AST) and total bilirubin, and low albumin. Cardiac enzymes showed mild elevation of Troponin T. Lactic acid was elevated. Laboratory test values are summarized in Table 1. The 12 lead electrocardiogram showed sinus tachycardia at 106 beats per minute with atrial sensed and biventricular paced rhythm.

Table 1 Laboratory test results on admission

The chest X-ray showed a diffuse miliary shadowing in both lungs suggestive of tuberculosis. There was mild ground-glass attenuation, especially in the right para-cardiac region. The heart was normal in size with CRT-D leads in place. There was no pleural effusion seen (Fig. 1).

Fig. 1
figure 1

Posterior anterior and lateral chest X-ray showing diffuse miliary shadowing in both lungs (Arrows). The cardiac resynchronization therapy-defibrillator device and leads in place

The high-resolution computed tomography (CT) chest was consistent with miliary TB. There was no axillary, hilar or mediastinal lymphadenopathy (Fig. 2).

Fig. 2
figure 2

Computed tomography (CT) chest axial plane showing diffuse randomly distributed ground-glass nodules (blue arrows) involving bilateral lungs consistent with military tuberculosis. Implantable cardioverter defibrillator leads seen (yellow arrows)

Based on the clinical presentation, the chest X-ray and CT chest findings, he was started on first-line anti-TB therapy in the form of rifampin 600 mg orally once daily, ethambutol 1200 mg orally once daily, pyrazinamide 2000 mg orally once daily, and isoniazid (isonicotinylhydrazide or INH) 300 mg orally once daily, with the addition of vitamin B6 25 mg orally once daily, and prednisone 60 mg orally once daily.

The trans-thoracic echocardiogram showed moderately dilated LV with severe global hypokinesis and severely reduced function (LVEF <25 %).The CRT-D device leads were seen in the right atrium and right ventricle. There were no obvious masses on the leads or on any of the cardiac valves to suggest vegetations. There was mild to moderate mitral regurgitation. The right ventricular systolic pressure was elevated at 30–40 mmHg. There was no pericardial effusion.

The transesophageal echocardiogram was performed, and it showed a mass in the superior vena cava (SVC) around the CRT-D device leads, extending into the right atrium (RA). A thin flickering structure consistent with a remnant of a Eustachian valve or Chiari network was also noted. No masses were seen on them to suggest free moving vegetations on other parts of the leads, but some thickening was seen on one segment of wire. It was very thin and could represent a fibrin/fibrous tissue deposit. No masses were seen on any of the four valves. A small pericardial effusion was seen and “tissue” lines in the visceral pericardium were seen which could be fibrin, a hematoma, or tissue related to tuberculosis pathology (Fig. 3).

Fig. 3
figure 3

Transesophageal echocardiogram at mid esophageal level showing mass in the right atrium attached to the lead

The blood cultures and urine culture were all negative. The work up was negative for HACEK group (Haemophilus species, Aggregatibacter species, Cardiobacterium hominis, Eikenella corrodens, and Kingella kingae), and other bacterial and viral infection including human immunodeficiency virus (HIV) and respiratory viruses.

Bronchoscopy and bronchoalveolar lavage were performed, and pathology examination showed a necrotizing granulomatous inflammation and special stains for AFB were positive. The culture showed Mycobacterium tuberculosis and sensitivity came back as sensitive to all first line anti-TB therapy.

His clinical course was complicated by acute renal failure with an increase in serum creatinine to 351 μmol/L and urea to 37 mmol/L. It was felt that the cause of his renal impairment was due to cardio-renal syndrome. It improved gradually and he did not require hemodialysis. He also had confusion and was noted to have a tonic–clonic seizure disorder. He was intubated, put on mechanical ventilation and started on anti-seizure treatment with IV levetiracetam (keppra) and phenytoin. Electroencephalogram showed a severe diffuse encephalopathy with periodic epileptiform discharges and continuous slow activity, generalized (delta coma). CT brain showed a preserved gray-white matter differentiation with no evidence of acute established territorial infarction, intra-axial or extra-axial hemorrhage, hydrocephalus, mass effect, or midline shifting.

Lumbar puncture was performed and cerebrospinal fluid (CSF) analysis showed a pale yellow, slightly turbid fluid with labs of: RBC 110 (normally 0), WBC 300 × 109/L (0–5 × 106/L) with neutrophils 72, band 1, lymphocytes 22, and monocytes 5. Glucose was 0.12 mmol/L (2.2–3.90 mmol/L), and protein 3580 mg/L (150–450 mg/L). Mycobacterium tuberculosis complex DNA was positive and Mycobacterium tuberculosis complex was isolated from the CSF. These findings were consistent with TB meningitis. Furthermore, he had melena with a drop in his hemoglobin to 69 g/L. He required transfusion of two units of packed red blood cells (PRBC). Upper gastroenterology endoscopy was performed, and it revealed a duodenal ulcer, which was cauterized. His thrombocytopenia continued and platelets dropped further to 14 × 109/L. Hematology service was involved and it was felt that his thrombocytopenia was secondary to his TB infection. Coombs test was positive and peripheral blood smear showed no significant schistocytes making thrombotic thrombocytopenic purpura (TTP) unlikely.

It was decided to remove his CRT-D device leads surgically due to the large size of the vegetations. Once he was relatively stable he was taken to the operating room and under general anesthesia a median sternotomy was performed and he was put on cardiopulmonary bypass machine. The RA was opened and the vegetation was noted to extend from the SVC to mid-RA (Fig. 4).

Fig. 4
figure 4

Vegetation on the lead

The vegetation was removed and sent for culture and sensitivity. The three leads were removed completely. Cardiopulmonary bypass was weaned off gradually with no difficulty. The patient tolerated the procedure and was transferred to the Cardiac Surgery Intensive Care Unit (CSICU) on inotropic support. The microbiology test of the vegetation revealed 10 colonies of Mycobacterium tuberculosis complex. In the CSICU, he was noted to have a high-grade fever and hemodynamic instability despite maximum inotropic support. He ultimately went into a multi-organ failure and died a few days later.

Discussion

We are presenting a case of miliary tuberculosis (TB) with infective endocarditis involving cardiac resynchronization therapy device leads. We believe that this patient had a miliary TB that was complicated by infection of the CRT-D devices leads due hematogenous spread. There was no evidence of device pocket infection and miliary TB preceded the CDR-IE.

Infection of CIEDs is a serious cardiovascular disease which is associated with a high mortality. The incidence of CIEDs infection in a population-based study is 1.9 per 1000 device-years with a higher probability of infection after implantable cardioverter defibrillator (ICD) compared with permanent pacemaker (PPM) implantation [4]. The diagnosis and management of CIEDs infections are difficult [5].

Local device infection is defined as an infection limited to the pocket of the cardiac device and is clinically suspected in the presence of local signs of inflammation at the generator pocket, including warm site, erythema, fluctuance, wound dehiscence, erosion, tenderness or purulent drainage [6]. CDR-IE is defined as infection extending to the electrode leads, cardiac valve leaflets or endocardial surface [1]. As stated above our patient clearly had a CDR-IE secondary to hematogenous spread of the miliary TB.

Several factors have been associated with CIED infections, which may be divided firstly into patient factors such as renal failure, corticosteroid use, congestive heart failure, hematoma formation, diabetes mellitus, anticoagulation use, and fever within the 24 h before implantation [611]. Secondly, procedural factors such as the type of intervention [12, 13], device revisions, the site of intervention, the number of indwelling leads, the use of pre-procedural temporary pacing, failure to administer perioperative antimicrobial prophylaxis [14], and operator experience [11] all play a role.

Our patient had a CRT-D device with three leads which put him at higher risk for CIED infection.

In terms of microbiological causes of CDR-IE, Staphylococci especially Coagulase-Negative species (CoNS), accounts for 60–80 % of cases in most of the reported series [15, 16]. A variety of CoNS species have been described [6, 15]. Corynebacterium spp., Propionibacterium acnes, Gram-negative bacilli and Candida spp. are rarely identified as pathogens in CIED infection [6, 15].

CIED infection due to Mycobacterium species is an uncommon but a well-recognized entity.

Review of literature showed 25 case reports of CIED related infections due to Mycobacterium species [1739], with two different Mycobacteria species in one patient [20], and three cases in one report [31]. Tables 2 and 3 show Mycobacterial infections of implanted pacemakers and ICDs respectively, as reported in literature. The infection was mostly pocket infection and rarely bacteremia with leads involvement. The infection occurred between 8 days and 20 years from the last device related procedure. It occurred with both transvenous [17, 18, 2022, 2427, 30, 31, 3339] and epicardial device implantations [19, 23, 28, 29, 32]. Mycobacterium tuberculosis was reported in seven cases [18, 23, 28, 31, 36] with mostly pocket infection. In the two cases with miliary TB, both patients died. The first patient died in hospital after a prolonged admission due to renal and respiratory failure, and recurrent ventricular fibrillation [18]. The second patient died after discharge while awaiting re-implantation of ICD in spite of the fact he had been equipped with a LifeVest [36]. The late presentation, severe systemic involvement, and underlying severe heart failure were key risk factors in our patient’s ultimate outcome. Mycobacterium fortuitum was reported in nine cases [2022, 24, 26, 27, 30, 38, 39] with pocket infection in five cases and pocket with lead or bacteremia infection in four cases. Mycobacterium abscessus was reported in two cases [19, 33] with pocket infection. Mycobacterium goodii was reported in two cases [25, 29] with pocket infection plus bacteremia in the first case. Mycobacterium avium complex [17], and M. avium intracellulare complex [32] in one case causing epicardial PM and ICD pocket infection respectively. Also it was reported with M. chelonae [20], M. peregrinum [34], and M. phlei [37]. These organisms are commonly found in the environment and likely contaminate the device or pocket at the time of insertion or during surgical manipulation. Reactivation of M. tuberculosis causing a CIED infection has also been identified in some of these case reports [23, 28, 31].

Table 2 Mycobacterial infections of implanted pacemakers as reported in literature
Table 3 Mycobacterial Infections of implanted cardioverter defibrillators as reported in literature

The widespread use of AFB staining and mycobacterial cultures has undoubtedly increased diagnostic accuracy [40]. Ziehl–Neelsen staining has a sensitivity of 50–80 % while that of blood culture is approximately 98 % [41, 42].

Early identification of the Mycobacterium species can provide predictable antimicrobial susceptibility patterns. The best chance of cure is obtained with a combination of at least two active antimicrobials given for a minimum of 4 weeks, plus removal of the CIEDs [43].

Conclusion

CIEDs infection due to Mycobacterium species is an uncommon but a well-known entity. Early diagnosis and prompt management may result in a good outcome. In case of suspected military TB early initiation of anti-TB therapy is recommended while awaiting culture results.

Abbreviations

°C:

celsius

AFB:

acid-fast bacilli

AST:

aspartate aminotransferase

CDR-IE:

cardiac device-related infective endocarditis

CIEDs:

cardiac implantable electronic devices

CK:

creatine kinase

CO2 :

carbon dioxide

CoNS:

coagulase-negative species

CRT-D:

cardiac resynchronization therapy-defibrillator

CSF:

cerebrospinal fluid

CSICU:

Cardiac Surgery Intensive Care Unit

CT:

Computed Tomography

HACEK group:

Haemophilus species, Aggregatibacter species, Cardiobacterium hominis, Eikenella corrodens, and Kingella kingae

HIV:

human immunodeficiency virus

ICD:

implantable cardioverter defibrillator

JVP:

jugular venous pressure

LVEF:

left ventricular ejection fraction

M:

Myobacterium

PPM:

permanent pacemaker

PRBC:

packed red blood cells

RA:

right atrium

SVC:

superior vena cava

TB:

tuberculosis

TBE:

tuberculosis endocarditis

TTP:

thrombotic thrombocytopenic purpura

References

  1. Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, Dulgheru R, El Khoury G, Erba PA, Iung B, Miro JM, Mulder BJ, Plonska-Gosciniak E, Price S, Roos-Hesselink J, Snygg-Martin U, Thuny F, Tornos Mas P, Vilacosta I, Zamorano JL, Document Reviewers, Erol Ç, Nihoyannopoulos P, Aboyans V, Agewall S, Athanassopoulos G, Aytekin S, Benzer W, Bueno H, Broekhuizen L, Carerj S, Cosyns B, de Backer J, de Bonis M, Dimopoulos K, Donal E, Drexel H, Flachskampf FA, Hall R, Halvorsen S, Hoen B, Kirchhof P, Lainscak M, Leite-Moreira AF, Lip GY, Mestres CA, Piepoli MF, Punjabi PP, Rapezzi C, Rosenhek R, Siebens K, Tamargo J, Walker DM. ESC guidelines for the management of infective endocarditis: the task force for the Management of Infective Endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J. 2015;36(44):3075–128. doi:10.1093/eurheartj/ehv319.

    Article  PubMed  Google Scholar 

  2. Liu A, Nicol E, Hu Y, Coates A. Tuberculous endocarditis. Int J Cardiol. 2013;167(3):640–5. doi:10.1016/j.ijcard.2012.08.009.

    Article  PubMed  Google Scholar 

  3. Gandhi T, Crawford T, Riddell J 4th. Cardiovascular implantable electronic device associated infections. Infect Dis Clin North Am. 2012;26(1):57–76. doi:10.1016/j.idc.2011.09.001.

    Article  PubMed  Google Scholar 

  4. Uslan DZ, Sohail MR, St Sauver JL, Friedman PA, Hayes DL, Stoner SM, Wilson WR, Steckelberg JM, Baddour LM. Permanent pacemaker and implantable cardioverter defibrillator infection: a population-based study. Arch Intern Med. 2007;167(7):669–75. doi:10.1001/archinte.167.7.669.

    Article  PubMed  Google Scholar 

  5. Nof E, Epstein LM. Complications of cardiac implants: handling device infections. Eur Heart J. 2013;34(3):229–36. doi:10.1093/eurheartj/ehs352.

    Article  PubMed  Google Scholar 

  6. Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, Steckelberg JM, Stoner S, Baddour LM. Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. J Am Coll Cardiol. 2007;49(18):1851–9. doi:10.1016/j.jacc.2007.01.072.

    Article  PubMed  Google Scholar 

  7. Klug D, Balde M, Pavin D, Hidden-Lucet F, Clementy J, Sadoul N, Rey JL, Lande G, Lazarus A, Victor J, Barnay C, Grandbastien B, Kacet S. Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study. Circulation. 2007;116:1349–55. doi:10.1161/CIRCULATIONAHA.106.678664.

    Article  PubMed  Google Scholar 

  8. Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, Steckelberg JM, Stoner SM, Baddour LM. Risk factor analysis of permanent pacemaker infection. Clin Infect Dis. 2007;45(2):166–73. doi:10.1086/518889.

    Article  PubMed  Google Scholar 

  9. Bloom H, Heeke B, Leon A, Mera F, Delurgio D, Beshai J, Langberg J. Renal insufficiency and the risk of infection from pacemaker or defibrillator surgery. Pacing Clin Electrophysiol. 2006;29(2):142–5. doi:10.1111/j.1540-8159.2006.00307.x.

    Article  PubMed  Google Scholar 

  10. Lekkerkerker JC, van Nieuwkoop C, Trines SA, van der Bom JG, Bernards A, van de Velde ET, Bootsma M, Zeppenfeld K, Jukema JW, Borleffs JW, Schalij MJ, van Erven L. Risk factors and time delay associated with cardiac device infections: Leiden device registry. Heart. 2009;95(9):715–20. doi:10.1136/hrt.2008.151985.

    Article  CAS  PubMed  Google Scholar 

  11. Al-Khatib SM, Lucas FL, Jollis JG, Malenka DJ, Wennberg DE. The relation between patients’ outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating Medicare beneficiaries. J Am Coll Cardiol. 2005;46(8):1536–40. doi:10.1016/j.jacc.2005.04.063.

    Article  PubMed  Google Scholar 

  12. Johansen J, Nielsen J, Arnsbo P, Moller M, Pedersen A, Mortensen P. Higher incidence of pacemaker infection after replacement than after first implantation: experiences from 36,076 consecutive patients. Heart Rhythm. 2006;3:S102–3. doi:10.1016/j.hrthm.2006.02.310.

    Article  Google Scholar 

  13. Gould PA, Krahn AD. Canadian Heart Rhythm Society Working Group on Device Advisories. Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories. JAMA. 2006;295(16):1907–11. doi:10.1001/jama.295.16.1907.

    Article  CAS  PubMed  Google Scholar 

  14. DaCosta A, Kirkorian G, Cucherat M, Delahaye F, Chevalier P, Cerisier A, Isaaz K, Touboul P. Antibiotic prophylaxis for permanent pacemaker implantation: a meta-analysis. Circulation. 1998;97(18):1796–801. doi:10.1161/01.CIR.97.18.1796.

    Article  CAS  Google Scholar 

  15. Bongiorni MG, Tascini C, Tagliaferri E, Di Cori A, Soldati E, Leonildi A, Zucchelli G, Ciullo I, Menichetti F. Microbiology of cardiac implantable electronic device infections. Europace. 2012;14(9):1334–9. doi:10.1093/europace/eus044.

    Article  PubMed  Google Scholar 

  16. Tarakji KG, Chan EJ, Cantillon DJ, Doonan AL, Hu T, Schmitt S, Fraser TG, Kim A, Gordon SM, Wilkoff BL. Cardiac implantable electronic device infections: presentation, management, and patient outcomes. Heart Rhythm. 2010;7(8):1043–7. doi:10.1016/j.hrthm.2010.05.016.

    Article  PubMed  Google Scholar 

  17. Amin M, Gross J, Andrews C, Furman S. Pacemaker infection with Mycobacterium avium complex. Pacing Clin Electrophysiol. 1991;14(2 Pt 1):152–4. doi:10.1111/j.1540-8159.1991.tb05083.x.

    Article  CAS  PubMed  Google Scholar 

  18. Doherty JG, Rankin R, Kerr F. Miliary tuberculosis presenting as infection of a pacemaker pulse-generator pocket. Scott Med J. 1996;41(1):20–1. doi:10.1177/003693309604100108.

    CAS  PubMed  Google Scholar 

  19. Cutay AM, Horowitz HW, Pooley RW, Van Horn K, Wormser GP. Infection of epicardial pacemaker wires due to Mycobacterium abscessus. Clin Infect Dis. 1998;26(2):520–1. doi:10.1086/517106.

    Article  CAS  PubMed  Google Scholar 

  20. Verghese S, Mullaseri A, Padmaja P, Subhadra AC, Cherian KM. Pacemaker implant site caused by atypical mycobacteria. Indian Heart J. 1998;50(2):201–2.

    CAS  PubMed  Google Scholar 

  21. Sharma S, Tleyjeh IM, Espinosa RE, Costello BA, Baddour LM. Pacemaker Infection due to Mycobacterium fortuitum. Scand J Infect Dis. 2005;37:66–7.

    Article  PubMed  Google Scholar 

  22. Hemmersbach-miller M, Cardenes-Santana MS, Conde-Martel A, Bolanos-Guerra HA, Campos-Herrer MI. Cardiac device infections due to Mycobacterium fortuitum. Can J Infect Dis Med Microbiol. 2005;16(3):183–5.

    PubMed  PubMed Central  Google Scholar 

  23. Hellwig T, Ou P, Offredo C, Stephany D, Bonnet D, Sidi D. Unusual chronic pacemaker infection by Mycobacterium tuberculosis in a pediatric patient. J Thorac Cardiovasc Surg. 2005;130(3):937–8. doi:10.1016/j.jtcvs.2005.04.016.

    Article  PubMed  Google Scholar 

  24. Pastor E, Luz Andre A, Llombart M, Chiner E. Mycobacterium fortuitum: a rare cause of pacemaker infection [Article in Spanish]. Enferm Infec Microbiol Clin. 2006;24(2):136–7.

    Article  Google Scholar 

  25. Toda H, Sato K, Iimori M, Yamazumi T, Furuta I, Satoh A, Katsukawa C. A case of Mycobacterium goodii infection with isolation from blood and a pacemaker lead [Article in Japanese]. Kansenshogaku Zasshi. 2006;80(3):262–6.

    Article  PubMed  Google Scholar 

  26. Giannella M, Valerio M, Franco JA, Marin M, Bouza E, Munoz P. Pacemaker infection due to Mycobacterium fortuitum: the role of universal 16S rRNA gene PCR and sequencing. Diagn Microbiol Infect Dis. 2007;57(3):337–9. doi:10.1016/j.diagmicrobio.2006.08.010.

    Article  CAS  PubMed  Google Scholar 

  27. Siu CW, Cheng LC, Woo PC, Lau CP, Tse HF. A patient with relapsing pacemaker infection due to “Gram-positive bacilli”. Int J Cardiol. 2007;114(2):E40–1. doi:10.1016/j.ijcard.2006.07.211.

    Article  PubMed  Google Scholar 

  28. Kestler M, Reves R, Belknap R. Pacemaker wire infection with Mycobacterium tuberculosis: a case report and literature review. Int J Tuberc Lung Dis. 2009;13(2):272–4.

    CAS  PubMed  Google Scholar 

  29. Marchandin H, Battistella P, Calvet B, Darbas H, Frapier JM, Jean-Pierre H, Parer S, Jumas-Bilak E, Van de Perre P, Godreuil S. Pacemaker surgical site infection caused by Mycobacterium goodie. J Med Microbiol. 2009;58(Pt 4):517–20. doi:10.1099/jmm.0.006759-0.

    Article  PubMed  Google Scholar 

  30. Al Soub H, Al Maslamani M, Al Khuwaiter J, El Deeb Y, Abu Khattab M. Myocardial abscess and bacteremia complicating Mycobacterium fortuitum pacemaker infection case report and review of the literature. Pediatr Infect Dis J. 2009;28(11):1032–4. doi:10.1097/INF.0b013e3181aa6592.

    Article  PubMed  Google Scholar 

  31. Kumar A, Agrawal T. A study of unusual pacemaker infection by Mycobacterium tuberculosis in Indian patients. Indian Pacing Electrophysiol J. 2014;14(6):291–6.

    Article  PubMed  PubMed Central  Google Scholar 

  32. Katona P, Wiener I, Saxena N. Mycobacterium avium-intracellulare infection of an automatic implantable cardioverter defibrillator. Am Heart J. 1992;124(5):1380–1. doi:10.1016/0002-8703(92)90429-Y.

    Article  CAS  PubMed  Google Scholar 

  33. Kessler AT, Kourtis AP. Mycobacterium abscessus as a cause of pacemaker infection. Med Sci Monit. 2004;10(10):CS60–2.

    PubMed  Google Scholar 

  34. Short WR, Emery C, Bhandary M, O’Donnell JA. Misidentification of Mycobacterium peregrinum, the causal organism of a case of bacteremia and automatic implantable cardioverter defibrillator-associated infection, due to its unusual acid-fast staining characteristics. J Clin Microbiol. 2005;43(4):2015–7. doi:10.1128/JCM.43.4.2015-2017.2005.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Chrissoheris MP, Kadakia H, Marieb M, Libertin C. Pacemaker pocket infection due to Mycobacterium goodii: case report and review of the literature. Conn Med. 2008;72(2):75–7.

    PubMed  Google Scholar 

  36. Luckie M, Zaidi A, Woodhead M, Garratt C. Mycobacterium tuberculosis causing infection of an implantable biventricular defibrillator. Indian J Tuberc. 2010;57:213–5.

    PubMed  Google Scholar 

  37. Karnam S, Alla VM, Kwon J, Harbert T, Sharma A, Airey K, Mooss A. Mycobacterium phlei, a previously unreported cause of pacemaker infection: thinking outside the box in cardiac device infections. Cardiol J. 2011;18(6):687–90. doi:10.5603/CJ.2011.0034.

    Article  PubMed  Google Scholar 

  38. Hu Y, Bridge B, Wang J, Jovina I. Mycobacterium fortuitum causing infection of a biventricular pacemaker/implantable cardioverter defibrillator. Int J Mycobacteriol. 2012;1(4):221–3. doi:10.1016/j.ijmyco.2012.10.001.

    Article  PubMed  Google Scholar 

  39. Shah P, Vishnevsky A. Mycobacterium fortuitum device infection with subsequent endocarditis. The Medicine Forum. 2012;13: Article 13. http://jdc.jefferson.edu/tmf/vol13/iss1/13.

  40. El Khéchine A, Drancourt M. Diagnosis of pulmonary tuberculosis in a microbiological laboratory. Med Mal Infect. 2011;41(10):509–17. doi:10.1016/j.medmal.2011.07.012.

    Article  PubMed  Google Scholar 

  41. Murray SJ, Barrett A, Magee JG, Freeman R. Optimisation of acid fast smears for the direct detection of mycobacteria in clinical samples. J Clin Pathol. 2003;56(8):613–5. doi:10.1136/jcp.56.8.613.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  42. Moore DA, Evans CA, Gilman RH, Caviedes L, Coronel J, Vivar A, Sanchez E, Piñedo Y, Saravia JC, Salazar C, Oberhelman R, Hollm-Delgado MG, LaChira D, Escombe AR, Friedland JS. Microscopic-observation drug-susceptibility assay for the diagnosis of TB. N Engl J Med. 2006;355(15):1539–50. doi:10.1056/NEJMoa055524.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  43. El Helou G, Viola GM, Hachem R, Han XY, Raad II. Rapidly growing mycobacterial bloodstream infections. Lancet Infect Dis. 2013;13(2):166–74. doi:10.1016/S1473-3099(12)70316-X.

    Article  PubMed  Google Scholar 

Download references

Authors’ contributions

BAG concept/design, drafting article, critical revision of article, approval of article, statistics. HEW, MAS, JA, AAS and MH data analysis/interpretation, acquisition of data. All authors read and approved the final manuscript.

Acknowledgements

The authors want to express their appreciation to Ms. Sandra Keating and Ms. Suzanne Tobias for editing the manuscript of this research.

Competing interests

The authors declare that they have no competing interests.

Availability of data and materials

The dataset(s) supporting the conclusions of this article is (are) included within the article [and its additional files(s)].

Consent for publication

Written informed consent was obtained from the patient’s son for publication of this Case Report and any accompanying images..

Ethics approval and consent to participate

The study is approved by the Hospital Research Ethics Committee.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bandar Al-Ghamdi.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Al-Ghamdi, B., Widaa, H.E., Shahid, M.A. et al. Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature. BMC Res Notes 9, 414 (2016). https://doi.org/10.1186/s13104-016-2221-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13104-016-2221-1

Keywords