Table 2 Comparison of circulatory variables

From: Changes in cardiac function and hemodynamics during robot-assisted laparoscopic prostatectomy with steep head-down tilt: a prospective observational study

Variable

Pre-tilting (range)

Post-tilting (range)

P value

Basic hemodynamic variables

 Heart rate (/min)

60.0 (56.3–64.5)

59.0 (53.3–64.5)

0.148

 Systolic BP (mmHg)

116.0 (101.3–125.0)

127.5 (110.0–130.0)

0.001

 Diastolic BP (mmHg)

59.0 (55.0–72.5)

70.0 (61.0–80.0)

0.002

 ET-CO2 (mmHg)

36.0 (33.3–38.5)

37.5 (34.3–38.8)

0.080

 SpO2 (%)

100 (98.5–100)

99.5 (99.0–100)

0.625

FloTrac® sensor data

 Cardiac index (L/min/m2)

2.28 (2.17–2.55)

2.30 (2.20–2.85)

0.350

TEE data

 Cardiac output (L/min)

4.3 (3.8–5.1)

4.0 (3.1–4.7)

0.129

 Cardiac index (L/min/m2)

2.5 (2.2–3.0)

2.2 (1.7–2.8)

0.143

 Ejection fraction (%)

62.5 (57.0–67.3)

55.5 (50.5–60.8)

0.040

 Stroke volume (mL)

75.0 (61.0–89.5)

79.0 (59.3–87.0)

0.235

PreSep® catheter data

 ScvO2 (%)

83.0 (78.3–86.8)

85.0 (79.5–87.5)

0.195

INVOS™ oximeter data

 Left rSO2 (%)

64.0 (59.8–75.5)

66.5 (61.8–79.3)

0.034

 Right rSO2 (%)

64.5 (61.8–68.5)

69.5 (64.8–73.5)

0.003

  1. Data are expressed as medians with interquartile ranges
  2. ET-CO 2 end-tidal carbon dioxide, LVEDV left ventricular end-diastolic volume, rSO 2 regional saturation of oxygen, SpO 2 percutaneous oxygen saturation, ScvO 2 central venous blood oxygen saturation