Skip to main content

Table 2 Selected secondary outcomes, median (range) or n (%)

From: Hazards to avoid in future neonatal studies of nasal high-frequency oscillatory ventilation: lessons from an early terminated trial

 

nHFOV (n = 4)

nCPAP (n = 2)

Blood gas analysis 2 h after extubation

 pH

7.31 (7.20–7.36)

7.25a

 pCO2 (mmHg)

60 (52–63)

73a

 pO2 (mmHg)

32 (25–42)

35a

Other secondary outcomes

 Successful extubation for > 72 h

3 (75)

0 (0)

 Treatment failure

2 (50)

2 (100)

 Successful rescue treatment

1 (25)

0 (0)

 Reintubation

1 (25)

2 (100)

 Highly viscous secretions

2 (50)

0 (0)

 Duration of mechanical ventilation (days)

22.5 (15–54)

47 (40–54)

 Duration of supplemental oxygen (days)

70 (51–118)

81 (80–82)

 Intraventricular haemorrhage 3°–4°

0 (0)

2 (100)

 Death or moderate to severe bronchopulmonary dysplasiab

1 (25)

1 (50)

  1. aOne patient in the nCPAP group had no blood gas analysis due to reintubation less than 2 h after extubation.
  2. bCombined outcome of death or moderate to severe bronchopulmonary dysplasia