Skip to main content

Table 2 Validity and reliability of the Mini-Cog by study participants and medical staff

From: Checking the validity and reliability of the Japanese version of the Mini-Cog using a smartphone application

 

Mini-Cog score

Agreement of two categories

ρ, ICC (95% CI)

N

%

ICC (95% CI)

Criterion-related validity

0.442

40

100

Test–retest reliability

0.381 (0.085–0.616)

37

92.5

0.362 (−0.201–0.924)

  1. Criterion-related validity: Pearson’s correlation coefficient; test–retest reliability: ICC (1,1)