Validity and reliability of simple measurement device to assess the velocity of the barbell during squats

Abstract

Objectives

The velocity of a barbell can provide important insights on the performance of athletes during strength training. The aim of this work was to assess the validity and reliably of four simple measurement devices that were compared to 3D motion capture measurements during squatting. Nine participants were assessed when performing 2 × 5 traditional squats with a weight of 70% of the 1 repetition maximum and ballistic squats with a weight of 25 kg. Simultaneously, data was recorded from three linear position transducers (T-FORCE, Tendo Power and GymAware), an accelerometer based system (Myotest) and a 3D motion capture system (Vicon) as the Gold Standard. Correlations between the simple measurement devices and 3D motion capture of the mean and the maximal velocity of the barbell, as well as the time to maximal velocity, were calculated.

Results

The correlations during traditional squats were significant and very high (r = 0.932, 0.990, p < 0.01) and significant and moderate to high (r = 0.552, 0.860, p < 0.01). The Myotest could only be used during the ballistic squats and was less accurate. All the linear position transducers were able to assess squat performance, particularly during traditional squats and especially in terms of mean velocity and time to maximal velocity.

Introduction

To enhance the performance of well-trained athletes, specific variables of strength training are often required [1]. For the lower limb, traditional squats are used to enhance maximal force, and ballistic squats are used to enhance rapid power generation [1,2,3]. The velocity of the bar during squats appears to be a valid parameter for monitoring strength training [4, 5].

It has been shown that based on the average velocity of the bar during the concentric phase at submaximal loads, the one repetition maximum (1RM) weight can be estimated [4, 6, 7]. The decrease of the bar velocity within a set can be related to the fatigue of the musculoskeletal system [8]. Therefore, recording the bar velocity allows coaches to monitor and steer the training as well as define a lower velocity limit as criteria for finishing a set [7]. Furthermore, real-time feedback regarding the bar velocity seems to have a positive effect on training [9].

Recently, many different measurement devices, including linear position transducers (LPT) and accelerometer based systems, have been developed to assess kinematic parameters during strength training [10, 11], and according to [11], the establishing the validity and reliability of these devices is crucial. To assess the validity/reliability of such devices, previous studies have used force plates [10, 12], video [13], motion capture systems [11] or no reference system [14,15,16]. However, the assessment of measurement devices during traditional and ballistic squats with motion capture as a reference system is missing.

Therefore, the aim of this work was to determine the validity and reliability in terms of average and maximal velocity as well as the time to maximal velocity of the bar as assessed by four simple measurement devices during traditional and ballistic squats.

Main text

Methods

Nine participants (age: 30.9 ± 5.9 years; height: 182 ± 6 cm; weight: 92.0 ± 8.7 kg; 1RM: 171 ± 20 kg; experience in strength training 9.7 ± 5.5 years; bob athletes and powerlifters) were analyzed. All subjects were informed of the nature of the study and signed informed consent. The ETH Ethics Committee in Zürich, Switzerland (EK 2014-N-50) approved this study.

After a 5-min warm up, the participants performed 2 × 5 traditional squats (Fig. 1) with a weight of 70% of their 1RM and 2 × 5 ballistic squats (Additional file 1: Figure S1) with a weight of 25 kg, in a randomized order. The participants rested for 3 min between each set and for 5 min between the exercises.

Fig. 1
figure 1

Simple measurement devices: 1 = T-force, 2 = Tendo unit, 3 = GymAware, 4 = Myotest, 5 = Vicon, the makers were placed at both ends of the bar

Simultaneously, data was recorded from three linear position transducers [T-FORCE (version 2.3, T-FORCE Dynamic Measurement System, ERGOTECH Consulting, Murcia, Sp), Tendo Power (Tendo Power Analyzer Unit version 4.1.0, Tendo Sport Machines, Trecin, Slo) and GymAware (version 1.1.2, Kinetic Performance Technology, Mitchell, Aus)], an accelerometer-based system (Myotest, Myotest SA, Sion, CH), and a 3D motion capture system (16 camera Vicon System, Nexus 1.85, Vicon Motion Systems, Oxford, UK) with a sampling frequency of 100 Hz used as the gold standard (Fig. 1).

Based on the measurements from each device, the average velocity of the bar during the concentric phase (V mean ), the maximum velocity of the bar during the concentric phase (V max ), and the time to V max (t Vmax) were calculated using Excel (version 14.5.2, Microsoft USA). In order to assess the validity and reliability, the root mean square error (RMSE), respectively the Pearson correlation between these measures obtained with the gold standard and the simple measurement devices were calculated. The device was reliable if the correlation has a value of r > 0.8 and a significant correlation coefficient is present [17]. All the statistical calculations were performed in SPSS (version 22, IBM, Chicago USA).

Results

The resultant average velocity V mean for the traditional and ballistic squats were 0.75 ± 0.13 and 1.56 ± 0.20 m/s, respectively. An evaluation of the data measured by the Myotest during the traditional squat was not directly possible.

Traditional squats

All the correlations to the gold standard were significant (Table 1). The RMSE for V max was higher than the RMSE of V mean . For the average difference, no clear pattern was visible between the three different devices (Table 2).

Table 1 Differences, RMSE and correlations of the velocities of the bar Vmean, Vmax and t Vmax during traditional squats
Table 2 Differences, RMSE and correlations of the velocities of the bar Vmean, Vmax and t Vmax during ballistic squats

Ballistic squats

All the correlations to the gold standard were significant (Table 1). The RMSE for V max was higher than the RMSE of V mean . For the average difference, no clear pattern was visible between the three different LPT devices (Table 2). However, the velocity parameters were less reliable when measured using the accelerometer-based device.

Discussion

In this study, the reliability and validity of four different devices used to assess two different bar velocities during traditional and ballistic squats were evaluated.

All three LPT devices were able to reliably measure the parameters Vmax, Vmean and t Vmax. This is in agreement with results from the evaluation of the Tendo and T-Force systems with squats using a Smith machine and weight of 40 kg [14]. It is worth noting that the RMSE of V max was larger than the other parameters. This indicates that V max is a less robust measure and the values should be handled with great care.

A possible reason why the Myotest was not usable for evaluation of the traditional squats is the fact that here free squats were analyzed and not squats using a Smith machine. Resulting difficulties with the rotation of the bar have previously been reported [18]. No clear difference was observed between the three different LPT devices.

For the ballistic squats, the Myotest also produced reliable results. This is due to the fact that the Myotest procedure could be followed. Similar to our finding, Giroux et al. [10] observed higher correlations between the GymAware and a force plate compared to Myotest and a force plate. The observed correlations were likely lower when using the Myotest due to the fact that free squats were performed in the present study. While tV max showed similar correlations for the two bar velocities, the V mean and V max showed less reliability at the higher velocity. In agreement with the findings of Jidovtseff [7], the parameters V mean and tV mean can be evaluated with the LPTs used here. This is important for the use of such devices in practice to allow the estimation of 1RMs and the fatigue during the workout.

The questions if a device is “valid” is clearly dependent on the research question, respectively on the magnitude of the values that should be quantified. In this study, the RMSE was < 11% for the three LPT for the traditional and ballistic squats and < 15% for the Myotest. Knowledge about the RMSE’s can provide evidence if a specific research question can be assessed using these devices.

Future research should focus either towards more valid and reliable devices for a cheaper prize or on the quantification during training in order to assess the volume, performance, fatigue, influence of different training settings in order to allow an individual training evaluation and steering. Maybe in the future it also might be possible to feed mechano-biological models for the adaptation process or use the data in order to prevent overload and overtraining.

To conclude, for the evaluation of squat performance at different squatting speeds, the three LPTs are reliable, and in particular, the parameters V mean and tV max can be used to monitor and guide workouts.

Limitations

With the gold standard, the 3D path of the bar was evaluated; however, the LPT only analyzed linear motion. Therefore, the bar path and the velocity is underestimated by the LPTs. However, this represents a “real life” setting similar to practice. A possibility to get rid of this limitation would be to use a smith press to perform the squats.

References

  1. Cormie P, McGuigan MR, Newton RU. Adaptations in athletic performance after ballistic power versus strength training. Med Sci Sports Exerc. 2010;42:1582–98.

    Article  PubMed  Google Scholar 

  2. Lopez-Segovia M, Marques MC, van den Tillaar R, Gonzalez-Badillo JJ. Relationships between vertical jump and full squat power outputs with sprint times in u21 soccer players. J Hum Kinet. 2011;30:135–44.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Requena B, Garcia I, Requena F, de Villarreal ES, Cronin JB. Relationship between traditional and ballistic squat exercise with vertical jumping and maximal sprinting. J Strength Cond Res. 2011;25:2193–204.

    Article  PubMed  Google Scholar 

  4. González-Badillo JJ, Marques MC, Sánchez-Medina L. The importance of movement velocity as a measure to control resistance training intensity. J Hum Kinet. 2011;29A:15–9.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Izquierdo M, González-Badillo JJ, Häkkinen K, Ibáñez J, Kraemer WJ, Altadill A, Eslava J, Gorostiaga EM. Effect of loading on unintentional lifting velocity declines during single sets of repetitions to failure during upper and lower extremity muscle actions. Int J Sports Med. 2006;27:718–24.

    Article  CAS  PubMed  Google Scholar 

  6. Bazuelo-Ruiz B, Padial P, Garcia-Ramos A, Morales-Artacho AJ, Miranda MT, Feriche B. Predicting maximal dynamic strength from the load-velocity relationship in squat exercise. J Strength Cond Res. 2015;29:1999–2005.

    Article  PubMed  Google Scholar 

  7. Jidovtseff B, Harris NK, Crielaard JM, Cronin JB. Using the load-velocity relationship for 1RM prediction. J Strength Cond Res. 2011;25:267–70.

    Article  PubMed  Google Scholar 

  8. Sanchez-Medina L, Gonzalez-Badillo JJ. Velocity loss as an indicator of neuromuscular fatigue during resistance training. Med Sci Sports Exerc. 2011;43:1725–34.

    Article  PubMed  Google Scholar 

  9. Jovanović M, Flanagan EP. Researched applications of velocity based strength training. J Aust Strength Cond. 2014;22:58–69.

    Google Scholar 

  10. Giroux C, Rabita G, Chollet D, Guilhem G. What is the best method for assessing lower limb force-velocity relationship? Int J Sports Med. 2015;36:143–9.

    CAS  PubMed  Google Scholar 

  11. Sato K, Beckham GK, Carroll K, Bazyler C, Sha Z, GH G. Validity of wireless device measuring velocity of resistance exercises. J Trainol. 2015;4:15–8.

    Article  Google Scholar 

  12. Hansen KT, Cronin JB, Newton MJ. The reliability of linear position transducer, force plate and combined measurement of explosive power-time variables during a loaded jump squat in elite athletes. Sports Biomech. 2011;10:46–58.

    Article  PubMed  Google Scholar 

  13. Drinkwater EJ, Galna B, McKenna MJ, Hunt PH, Pyne DB. Validation of an optical encoder during free weight resistance movements and analysis of bench press sticking point power during fatigue. J Strength Cond Res. 2007;21:510–7.

    PubMed  Google Scholar 

  14. Garnacho-Castano MV, Lopez-Lastra S, Mate-Munoz JL. Reliability and validity assessment of a linear position transducer. J Sports Sci Med. 2015;14:128–36.

    PubMed  PubMed Central  Google Scholar 

  15. Gomez-Piriz PT, Sanchez ET, Manrique DC, Gonzalez EP. Reliability and comparability of the accelerometer and the linear position measuring device in resistance training. J Strength Cond Res. 2013;27:1664–70.

    Article  PubMed  Google Scholar 

  16. Jennings CL, Viljoen W, Durandt J, Lambert MI. The reliability of the fitrodyne as a measure of muscle power. J Strength Cond Res. 2005;19:859–63.

    PubMed  Google Scholar 

  17. Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998;26:217–38.

    Article  CAS  PubMed  Google Scholar 

  18. Comstock BA, Solomon-Hill G, Flanagan SD, Earp JE, Luk HY, Dobbins KA, Dunn-Lewis C, Fragala MS, Ho JY, Hatfield DL, Vingren JL, Denegar CR, Volek JS, Kupchak BR, Maresh CM, Kraemer WJ. Validity of the Myotest(R) in measuring force and power production in the squat and bench press. J Strength Cond Res. 2011;25:2293–7.

    Article  PubMed  Google Scholar 

Download references

Authors’ contributions

SL designed the study, supported the measurements and data evaluation and wrote the main part of the manuscript. TL conducted the measurements and evaluated the data. FL designed the study, supported the measurements and the data evaluation. All authors read and approved the final manuscript.

Acknowledgements

The authors would like to thank all the participants who participated in this study.

Authors’ information

SL is Senior Scientist and Private docent and leads the Sport Biomechanics Group at the Institute for Biomechanics, ETH Zurich, Switzerland. TL Master of Science EHSM Magglingen, Performance Director Swiss Sliding, former athlete and Olympic medalist. FL is Research Assistant at the Swiss Federal Institute of Sport Magglingen (SFISM), Switzerland.

Competing interests

The authors declare that they have no competing interests.

Availability of data and materials

The datasets used and analyzed during the current study are available here: http://www.movement.ethz.ch/data-repository.html.

Consent for publication

The participants provided written approval for the use of the images.

Ethics approval and consent to participate

All authors abide by the Ethics Committee of ETH Zurich, Switzerland ethical rules of disclosure. All participants gave written consent to be part of this study.

Funding

This research received no external funding.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Silvio Lorenzetti.

Additional file

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lorenzetti, S., Lamparter, T. & Lüthy, F. Validity and reliability of simple measurement device to assess the velocity of the barbell during squats. BMC Res Notes 10, 707 (2017). https://doi.org/10.1186/s13104-017-3012-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13104-017-3012-z

Keywords