Skip to main content

Evaluation of loop-mediated isothermal amplification (LAMP) assay for detection of aprV2 positive Dichelobacter nodosus in-field by secondary users

Abstract

Objective

Dichelobacter nodosus is the primary aetiological agent of footrot in sheep. Ovine footrot causes considerable economic losses and substantial animal welfare issues in the Australian sheep industry. Current methods for detecting D. nodosus are difficult, laborious and time-consuming. Recently, we developed a robust LAMP assay (VDN LAMP) that was able to identify aprV2 positive D. nodosus in-field. A major advantage of LAMP technology is the ability of the assay to be performed by non-specialists with minimal training. We aimed to assess the performance of the VDN LAMP in-field in comparison to a laboratory-based aprV2/aprB2 rtPCR when used by secondary users after training by the authors.

Results

Two animal health officers (termed secondary users) from Department of Primary Industries and Regions, South Australia (PIRSA) were trained in the use of VDN LAMP, before carrying out in-field testing on several locations in South Australia. The performance of VDN LAMP assay by secondary user 1 was shown to successfully detect 73.91% (nā€‰=ā€‰53) aprV2 positive samples, while secondary user 2 detected 37.93% (nā€‰=ā€‰30) aprV2 positive samples. Overall, the ability to identify virulent D. nodosus by VDN LAMP by secondary users was mixed for various reasons, however, this could be rectified by additional training and commercial production of the LAMP kits to increase stability. We envisaged in the future VDN LAMP will able to be used by non-specialists to aid control programs.

Introduction

The causative agent of footrot is D. nodosus, a highly contiguous aerotolerant anaerobe that has the ability to digest hoof material [1]. This results in painful lesions and from the soft underlying tissue of the sheep foot that leads to major welfare and economic concerns. Current testing for D. nodosus causing ovine footrot relies on time-consuming and labour-intensive laboratory procedures that can take up to 3ā€“4Ā weeks for results [2]. This inability to identify D. nodosus rapidly allows the infection to spread throughout the farm.

We and others have investigated the use of molecular diagnostics for footrot by PCR and rtPCR [3, 4]. These molecular tests mainly discriminate D. nodosus based on presence of aprV2 and aprB2 encoding for proteases. Strains possessing AprV2 can cause clinically virulent disease, while AprB2 may cause clinically benign disease [5]. Despite the increased speed of these tests, they still require sending samples to a specialised laboratory. We recently developed a pen-side test using loop-mediated isothermal amplification (LAMP) technology to determine if sheep were infected with aprV2 positive strains of D. nodosus which we have termed VDN LAMP [6, 7]. VDN LAMP has the potential to inform local treatment decisions for the management of footrot in real time. This may help to identify infections prior to severe lesion development, leading to early treatment and reduced spread, or to confirm the presence of D. nodosus in the lesion.

LAMP assays have several benefits over other molecular tests, as they are in-field, fast, robust and do not require high-level technical expertise to perform [8]. Despite many advantages of LAMP, very few studies have assessed use by non-technical personnel. Here, we have evaluated the performance of VDN LAMP as used by secondary users to detect aprV2 positive D. nodosus from foot swabs collected in-field.

Main text

Materials and methods

Training

PIRSA animal health staff were given one 4-h workshop on LAMP use in August 2017 by the primary user (NB). The workshop included background information on molecular diagnostics/LAMP and a run through of sample collection, processing, and a LAMP run with freshly collected samples. Materials provided included pre-made kits, a one-page LAMP workflow and a booklet containing detailed workflow instructions. Two PIRSA animal health staff were chosen as final secondary users, neither person has a significant background in laboratory techniques. These secondary users were provided with kits by the primary user and then performed VDN LAMP over the course of usual FR disease investigations.

Sample collection and VDN LAMP for aprV2 positive D. nodosus detection

The samples were collected by Department of Primary Industries and Regions, South Australia animal health officers from the interdigital skin of lame sheep as part of routine diagnostic testing. Current clinical foot scores of the sheep feet were recorded and the single highest scored foot was sampled. Two swabs per sampled sheep were collected simultaneously and used as biological duplicates. One swab was used for aprV2/aprB2 rtPCR and the second for immediate in-field processing with VDN LAMP.

Swabs for aprV2/aprB2 rtPCR were collected as previously described [3]. Swabs for in-field processing with VDN LAMP were placed into 500Ā ĀµL alkaline polyethylene glycol, pH 13.0. Swab heads were snapped into the buffer tubes and left in, with collection and processing occurring at ambient temperature. Sample processing and VDN LAMP reactions were carried out as previously described Best et al. [7], with each kit containing the required reagents in volumes appropriate for the processing of eight samples. Purified genomic gDNA from arpV2 positive D. nodosus strain A198 was used as a positive control for each run.

rtPCR for detection of D. nodosus

Samples for rtPCR had all nucleic acids present extracted and purified as described previously [3]. The presence of aprV2 and/or aprB2 in samples were identified using primers, probes and cycling conditions as described by StƤuble et al. [4]. The AgPath-IDTM One-Step RT-PCR Kit (Ambion, Austin, USA) was used as master mix according to manufacturerā€™s instructions, adapted for 10Ā ĀµL final volume. Reactions and analysis were carried out on the Mic rtPCR Cycler (Bio Molecular Systems, Queensland, Australia), using auto threshold detection and bulk analysis.

Statistical analysis

Sample results were defined as follows, and only samples with complete data collection were used for analysis;

VDN LAMP positiveā€”sample has both a Tp (<ā€‰20Ā min) and Tm (87.7ā€“88.7Ā Ā°C).

VDN LAMP negativeā€”sample has only a Tp or Tm, or the Tm does not fall within the above range, or no Tp and Tm.

rtPCR aprV2 positiveā€”has an rtPCR result in the aprV2 channel with a Ctā€‰<ā€‰35.

rtPCR aprV2 negativeā€”has an aprV2 Ctā€‰ā‰„ā€‰35, is aprB2 positive, or negative for D. nodosus.

Samples with Ctā€™s above 35 are considered negative due to a lack of clinical relevance (2). The sensitivity (Se) of VDN LAMP is defined as the percentage of VDN LAMP positive samples within rtPCR aprV2 positive samples, and the specificity (Sp) the percentage of VDN LAMP negative samples within rtPCR aprV2 negative samples. Se, Sp, NPV and PPV were calculated using GraphPad Prism 6. Run success is defined as the positive control amplifying before 20Ā min with a Tm between 87.7ā€“88.7Ā Ā°CĀ and the negative control failing to amplify.

Results

A total of 83 sheep from 17 farms are included in the pilot study, sampled from October 2017 to February 2018. Secondary user 1 was based in Naracoorte. Samples were processed on-farm or collected and transported back to the office for processing. Secondary user 1 sampled a total of 53Ā sheep, from 11 farms. A total of 3 runs were unsuccessful, and a sensitivity of 73.91% and specificity of 100% was seen (TableĀ 1). Secondary user 2 was based in Nuriootpa. Samples were processed on the farm, with a total of 30 sheep from 6 properties provided. Only 2 runs were successful, and the overall sensitivity of 37.93% and specificity of 100% was seen (TableĀ 2).

TableĀ 1 Individual farm summary of the success of LAMP run, the number of VDN LAMP and rtPCR samples positive for aprV2, the sensitivity seen on that farm and the month of collection by secondary user 1
TableĀ 2 Individual farm summary of the success of LAMP run, the number of VDN LAMP and rtPCR samples positive for aprV2, the sensitivity seen on that farm and the month of collection by secondary user 2

Data from secondary user 1 and 2 were also analysed together to provide an overall data set. Combining data shows a sensitivity of 60%, and specificity of 100%, with 46/75 rtPCR aprV2 positive samples identified in-field by LAMP and secondary users (TableĀ 3). When all samples were grouped based on clinical score, sensitivity was highest in those feet scored 4 (80%), 5 (71.43%), and lowest in those scored 2 (38%) and 3 (46.15%) (Additional file 1: Table S1).

TableĀ 3 Agreement of aprV2 designation between VDN LAMP and rtPCR for allĀ secondary users

Discussion

We have examined the overall performance of the VDN LAMP assay to detect virulent D. nodosus when used by non-specialist. VDN LAMP, in the hands of secondary users, showed 60% sensitivity, and 100% specificity. This is in comparison to a sensitivity of 89% and specific of 97%, under ideal conditions, in a study performed by the primary users [6]. Some of the major issues associated with decreased sensitivity of the VDN LAMP assay was the quality control of reagents, contamination and thresholds hold settings. There were instances of delays in transit of the prepared reagent kits between Melbourne and both locations in South Australia. This resulted in incorrect storage of reagents and subsequent poor performance, in some instances failure of controls and therefore VDN LAMP run. This issue may be resolved by the commercialisation of the test, and the creation of dried reagents/kits suitable for transport at ambient temperature. There was also some recorded variation in performance of positive control. This again may be due to variations in delivery times and conditions, physical addition of the sample, or temperature fluctuations. The positive control should ideally amplify in under 13Ā min, however, was in some instances amplifying later, indicating degradation. It may be possible to include an internal positive control that is less susceptible to degradation, and fluctuations in transport conditions or mechanical errors.

There was one instance of contamination where the negative control amplified. It was difficult to identify the source, so all reagents were disposed of, and equipment bleached. New reagents and bleaching appeared to remedy the situation. As the secondary users are not specialists, additional training of users to decrease the risk of contamination and the development of dried kits that require less handling could help in mitigating the contamination risk.

Additional training could also include data collection, or improvements upon the form used for this study, as sometimes the information provided was unclear. Streamlining the data collection process to create a single location for all information may be of benefit to improving ease of use and clarity of information. This may be through additional labelling on LAMP machine, such as sample labels to include sample information (such as score) that can be read directly on LAMP run files, development of software that integrates assistance by contacting ā€œprimary userā€ and LAMP machine, or integration of data collection into existing frameworks.

Automatic thresholds as set on the GenieIII software were used throughout the study. When looking at the LAMP data files, some annealing peaks are present but are not above the pre-set threshold and so are not included as VDN LAMP positive. This was most apparent in secondary user 2 data. Five additional samples would be VDN LAMP positive with the lowering of the pre-set threshold. A lowering of threshold would increase sensitivity but may also increase false positives. Pre-set thresholds have been appropriate in other VDN LAMP studies and would need to be considered in the context of the intended application of the assay by secondary users.

These results give a greater insight into the use of LAMP technology by non-specialist with clear routes to improving performance with secondary users. This information will help in the deployment of VDN LAMP assay and other diagnostics-based LAMP technology by various Australian Government agencies.

Limitations

The limitations of this study include a small sample size of sheep, limited training of staff, and less than ideal transport conditions for reagents.

Availability of data and materials

The information supporting the conclusions of this article is included in the article.

Abbreviations

rtPCR:

quantitative polymerase chain reaction

Tp:

time to positive

Tm:

annealing temperature

LAMP:

loop-mediated isothermal amplification

PIRSA:

Department of Primary Industries and Regions, South Australia

References

  1. Egerton JR, Roberts DS, Parsonson IM. The aetiology and pathogenesis of ovine foot-rot: I. A histological study of the bacterial invasion. J Comp Pathol. 1969;79(2):207ā€“15.

    ArticleĀ  CASĀ  Google ScholarĀ 

  2. Claxton PD, Ribeiro LA, Egerton JR. Classification of Bacteroides nodosus by agglutination tests. Aust Vet J. 1983;60(11):331ā€“4.

    ArticleĀ  CASĀ  Google ScholarĀ 

  3. Best N, Zanandrez L, Gwozdz J, Klien E, Buller N, Suter R, Rawlin G, Beddoe T. Assessment of a rtPCR for the detection of virulent and benign Dichelobacter nodosus, the causative agent of ovine footrot, in Australia. BMC Vet Res. 2018;14(1):252.

    ArticleĀ  Google ScholarĀ 

  4. StƤuble A, Steiner A, Frey J, Kuhnert P. Simultaneous detection and discrimination of virulent and benign Dichelobacter nodosus in sheep of flocks affected by foot rot and in clinically healthy flocks by competitive real-time PCR. J Clin Microbiol. 2014;52(4):1228ā€“31.

    ArticleĀ  Google ScholarĀ 

  5. Kennan RM, Han X, Porter CJ, Rood JI. The pathogenesis of ovine footrot. Vet Microbiol. 2011;153(1ā€“2):59ā€“66.

    ArticleĀ  CASĀ  Google ScholarĀ 

  6. Best N, Rawlin G, Suter R, Rodoni B, Beddoe T. Optimization of a loop mediated isothermal amplification (LAMP) assay for in-field detection of Dichelobacter nodosus with aprV2 (VDN LAMP) in victorian sheep flocks. Front Vet Sci. 2019;6:67.

    ArticleĀ  Google ScholarĀ 

  7. Best N, Rodoni B, Rawlin G, Beddoe T. The development and deployment of a field-based loop mediated isothermal amplification assay for virulent Dichelobacter nodosus detection on Australian sheep. PLoS ONE. 2018;13(9):e0204310.

    ArticleĀ  Google ScholarĀ 

  8. Li Y, Fan P, Zhou S, Zhang L. Loop-mediated isothermal amplification (LAMP): a novel rapid detection platform for pathogens. Microb Pathog. 2017;107:54ā€“61.

    ArticleĀ  CASĀ  Google ScholarĀ 

Download references

Acknowledgements

We would like to thank the participating sheep owners for their time and assistance during sample collection, and the PIRSA Animal Health Officers for sample collection.

Funding

No specific funding was granted for this project.

Author information

Authors and Affiliations

Authors

Contributions

NB was responsible for the experimental work, data analysis, and writing of the manuscript. BR, GR and TB coordinated the project, contributed to the experimental design, and reviewed the drafts. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Travis Beddoe.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

Additional file 1: Table S1.

VDN LAMP agreement to rtPCR aprV2 designation within clinical scoring groups for footrot for all 83 sheep.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Best, N., Rodoni, B., Rawlin, G. et al. Evaluation of loop-mediated isothermal amplification (LAMP) assay for detection of aprV2 positive Dichelobacter nodosus in-field by secondary users. BMC Res Notes 12, 534 (2019). https://doi.org/10.1186/s13104-019-4575-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13104-019-4575-7

Keywords