Skip to main content

Examining the interaction of different factors on pointing precision when using handheld laser pointers

Abstract

Objective

Laser pointers are common teaching tools used during lessons. The pointing precision may influence the teaching effectiveness. In this study, we examined the effect of four external factors, namely aiming distance, target size, light condition and colour of the laser beam on the pointing precision.

Results

Thirty participants (15 males and 15 females; age = 23.2 ± 4.3) were asked to aim at the target black circles with different sizes (diameters = 4 mm, 8 mm, 12 mm and 16 mm) from five various distances (2 m, 4 m, 6 m, 8 m and 10 m) at two brightness conditions (i.e., bright and dark) using two different coloured laser pointers (red and green). Three aiming parameters, namely number of hits, duration per hit and pointing precision were measured. Results showed that the aiming parameters were the highest with the aiming distance of 2 m and the use of green laser pointer towards larger target sizes regardless of the environmental brightness. Among all factors, aiming distance was the most important external factor that could influence pointing precision.

Introduction

Given its bright light emission ability and the nature of human eyes that tends to focus on a bright point of light, handheld laser pointer (sometimes termed laser pan) is widely utilized used as a signalling tool by educators for lectures and presentations [1], or as a teaching tool in surgery training [2, 3]. These applications have significantly improved the effectiveness of teaching and training. For example, teachers can walk across classroom and interact with their students while being able to point to their presentation screens or displays [4], while surgeons can indicate body landmarks or relevant areas of interest in surgery training [5]. However, a common problem of using the laser pointer is the pointing precision [6, 7]. Myers and colleagues [7] stated that the pointing precision was not easily maintained due to inherent human limitations (e.g., unsteady hands, poor spatial judgement), which may result in distractions and therefore negatively impact teaching and learning [6, 7].

Apart from the inherent human limitations, other external factors such as aiming distance, target size, light condition and colour of the laser beam may also affect the pointing precision. Nevertheless, no previous studies have examined the interactions of pointing precision with these external factors. How far should a presenter stand from the screen in order to aim accurately? Should the teacher turn on the lights of the classroom in order to aim accurately? Without a comprehensive study examining possible factors that can affect pointing precision, these questions remained unanswered. In the present study, we aimed to explore the interactions between the pointing precision and four external factors, namely aiming distance, target size, light condition and colour of the laser beam.

Main text

Methods

A total of thirty participants were recruited from the third author’s institution using the following inclusion criteria: (1) male or female; (2) 18–45 years of age; and (3) able to independently operate a laser pointer while standing. The exclusion criteria were: (1) aged above 45 years, or (2) unable to independently operate a laser pointer while standing. Written informed consent was obtained from participants. The study was approved by the Nanyang Technological University Institutional Review Board (IRB 2020-09-029). Demographic data of the participants is shown in Additional file 1: Table S1.

Data collection, measures and analysis

Green (model: Dobex DesignZ)—and red (model: Logitech R400) laser pointers were used in the present study. A digital camera (1920 × 1080 pixels, 24 fps; Canon G15 Power Shot) was used to record the pointing performance of the participants throughout the study. And a luxmeter (Walfront Smart Sensor AS803) was set up to measure the brightness of the experiment room. Four target black circles (printed on A4 size white paper) with diameters (4 mm, 8 mm, 12 mm and 16 mm) were put on a whiteboard. Five distances from the targets (2 m, 4 m, 6 m, 8 m and 10 m) were marked on the floor using measuring tapes. This distance range (i.e., from 2 to 10 m) is selected because educators commonly stand within such range from the screen according to our observation. There were two conditions of the experiment: bright and dark. For the bright condition, all the lights in the room were turned on with mean lux of 552 (SD = 103). For the dark condition, all the lights in the room were off with mean lux of 50 (SD = 18). The setup is presented in Additional file 2.

Each participant was asked to use the laser pointers of different colours to hit the target black circles as closely as possible from various distances at two brightness conditions (i.e., bright and dark). The duration of each trial was 10 s. In a standing position, participants were instructed to hit the target continuously for 10 s in each condition to their best effort. Sufficient time was provided for the participants to rest between trials. The orders of target sizes, aiming distances, laser beam colours and brightness conditions were randomized among all participants to minimize learning and fatigue effects. Each participant completed 80 trials in total (4 target sizes × 5 distances × 2 laser beam colours × 2 light conditions).

From the video recordings of the laser beam trajectories, three parameters of aiming performance were measured in each 10-s trial: (1) number of hits; (2) duration per hit and 3) pointing precision (i.e., percentage of the total duration of hits over 10 s). For good consistency in the timing measurements, all recorded video clips were evaluated by the same researcher (J. J. Poh) using the video analysis software Kinovea (version: 0.8.15; https://www.kinovea.org/).

Statistical analysis

Descriptive results were first presented for all conditions due to the exploratory nature of the study. Next, a series of repeated measures Analysis of Variance (ANOVA) were conducted to examine the interaction of different factors (distance × beam colour, distance × light, distance × target size) on pointing precision. JASP (version 0.14.1, JASP Team, 2020) was used for the statistical analysis, with significance level set at p < 0.05. Post-hoc analysis with Holm–Bonferroni adjustments were applied where appropriate.

Results

Number of hits: The number of hits corresponding to different conditions (i.e., aiming distance, target size, brightness condition and colour of laser pointer) is shown in Fig. 1. As shown in the figure, it is noted that the number of hits increased with aiming distance and target size regardless of brightness condition and colour of laser beam. Comparing with different target sizes, the number of hits was the highest with the largest target size (i.e., 16 mm in diameter).

Fig. 1
figure 1

The number of hits corresponding to different conditions

Duration per hit: The duration per hit corresponding to different conditions is shown in Fig. 2. The duration per hit decreased with increasing aiming distance regardless of the target size, brightness condition and colour of laser beam. Drastic decrease in the durations were observed when the distance increased from 2 to 4 m in all conditions.

Fig. 2
figure 2

The duration per hit corresponding to different conditions

Pointing precision: The pointing precision corresponding to different conditions is shown in Fig. 3. Statistical results showed for a fixed target size (16 mm) and beam colour (green), the pointing precision significantly decreased with increasing aiming distance (p < 0.001, η2p = 0.548). There was no difference between the bright and dark conditions (p = 0.174, η2p = 0.063). Post-hoc analysis revealed that pointing from 2 m was more accurate than all other distances (p < 0.001), while other pairwise differences were less obvious (4 m > 8 m, 10 m; 6 m > 10 m; 8 m > 10 m). Regarding the effect of laser beam colour, the pointing precision of green beam was significantly higher than that of the red beam (p < 0.001, η2p = 0.617) across all distances for a given target size (16 mm) and brightness (bright). Finally, there was a significant effect of target size (p < 0.001, η2p = 0.546) across all distances with no target × distance interaction. Post-hoc analysis showed that pointing at the smallest 4 mm target was significantly less accurate than 12 mm and 16 mm (p < 0.01) for a given brightness (bright) and beam colour (green). The 8 mm target was also less accurate than the 16 mm target (p = 0.014).

Fig. 3
figure 3

The pointing precision corresponding to different conditions

Discussion

The purpose of the study was to explore whether pointing precision of laser pointer were influenced by with four external factors, namely aiming distance, target size, brightness condition and colours of laser beam. Overall, the results showed that the aiming distance, laser beam colour and the target size were the major factors for the pointing precision. Importantly, the aiming distance of 2 m appeared to be critical for the pointing accuracy as the present study showed that all parameters have dropped substantially when the aiming distance increased beyond 2 m. This finding is in line with Myers et al.’s study [7], which concluded that interaction between laser pointer and computer display tended to be imprecise and error-prone with the increasing aiming distance and decreasing screen size [7].

Regarding to the colour of the laser beam, all aiming parameters were generally higher than in green laser beam condition that those in red laser beam condition across all aiming distances, target sizes and brightness settings. One possible explanation may lie on the difference in colour perception by human eyes. Studies showed that human eyes perceive green colour better than any colour of the spectrum [8, 9]. Galang and colleagues [8] suggested that participants tended to have a better estimation of laser trajectory and laser endpoint when green coloured laser beam was used. Regarding the brightness of the room, the present study showed no statistical difference in pointing precision and that all aiming parameters were similar under the rather extreme bright and dark conditions. This finding suggests that under normal classroom condition, brightness may not be a dominant factor limiting the aiming performance of the teacher. Our study, however, did not evaluate if students respond and focus better with the red or green laser beam. Future research is warranted to further investigate in this aspect.

Limitations

Several limitations exist in the present study that require attention in future investigations. First, there is a lack of measurement of laser beam trajectory. Without such measurement, it is difficult to explain why there would be a difference of the pointing precision between different lighting, target size and distance conditions. Second, this study is constrained by one single trial for each aiming performance considering the large volume of data (80 trials per participant). While learning effect of the aiming performance should be minimized, reliability of the result is also important. Future similar studies may consider to focus on key factors and conducting additional trials for each aiming performance, and to check the test–retest reliability on different days. Third, we did not measure the angle of wrist of participants when they were aiming the target, which may confound the relationship between distance and accuracy. Future study should follow the protocol by Myers et al.’s [7] study that measured the angle of wiggle (i.e., the angle of wrist of participant in this case). In this way, we could then conclude whether the diameter of target would be promotional to the distance. Finally, the current study design could not indicate whether 2 m is the optimal distance for educators to stand from the screen for the best laser-pointing accuracy. It could simply be due to the fact that 2 m is the shortest distance measured in the present study. Future work can determine an optimal window for high pointing precision when using a handheld laser pointer.

Availability of data and materials

The dataset generated and analysed during the current study is publicly available and can be accessed via the NIE Data Repository (https://doi.org/10.25340/R4/BDQBVF).

References

  1. Neffendorf JE, Hildebrand GD, Downes SM. Handheld laser devices and laser-induced retinopathy (LIR) in children: an overview of the literature. Eye. 2019;33:1203–14.

    Article  Google Scholar 

  2. Heinrich F, Huettl F, Schmidt G, Paschold M, Kneist W, Huber T, Hansen C. HoloPointer: a virtual augmented reality pointer for laparoscopic surgery training. Int J Comput Assist Radiol Surg. 2021;16:161–8.

    Article  Google Scholar 

  3. Ursic CM, Coates NE, Fischer RP. The pocket laser pointer as a teaching tool in laparoscopic surgery. Surg Laparosc Endosc. 1997;7:47–8.

    Article  CAS  Google Scholar 

  4. Golub E. To point or click, that is the question. Edu Tech. 2015;55:39–43.

    Google Scholar 

  5. Jayaraman S, Apriasz I, Trejos AL, Bassan H, Patel RV, Schlachta CM. Novel hands-free pointer improves instruction efficiency in laparoscopic surgery. Surg Inno. 2019;16:73–7.

    Article  Google Scholar 

  6. König WA, Gerken J, Dierdorf S, Reiterer H. Adaptive pointing—design and evaluation of a precision enhancing technique for absolute pointing devices. Berlin: Springer; 2009.

    Book  Google Scholar 

  7. Myers BA, Bhatnagar R, Nichols J, Peck C H, Kong D, Miller R, Long AC. Interacting at a distance: measuring the performance of laser pointers and other devices. In: proceedings of the SIGCHI conference on human factors in computing systems. 2002.

  8. Galang J, Restelli A, Hagley EW, Hadler J, Clark CW. A green laser pointer hazard. Inter Laser Safety Conf. 2011; 296–300.

  9. Rushton WAH, Baker HD. Red/green sensitivity in normal vision. Vis Res. 1964;4:75–85.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Mr. Pan Jingwen for his assistance in the preparation of figures and tables.

Funding

This study is funded by Nanyang Technological University under the URECA Undergraduate Research Programme, Singapore and Individual Research Fund (#R6552), Hong Kong.

Author information

Authors and Affiliations

Authors

Contributions

PWK and JJP deigned the study and coordinated the data collection. CYAT wrote and revised the manuscript. DTPF provided inputs in the study design and proofread the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Choi Yeung Andy Tse.

Ethics declarations

Ethics approval and consent to participate

The study has been approved by Nanyang Technological University Institutional Review Board (Ref. No. IRB-2020-09-029) and consent forms were obtained from all the participants.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

: Table S1. Demographic statistics of participants (n = 30).

Additional file 2.

Set-up of the experiment.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tse, C.Y.A., Kong, P.W., Poh, J.J. et al. Examining the interaction of different factors on pointing precision when using handheld laser pointers. BMC Res Notes 15, 93 (2022). https://doi.org/10.1186/s13104-022-05962-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13104-022-05962-z

Keywords