Skip to main content

Reliability of mixed dentition space analysis using a digital model obtained from an optical impression: a preliminary study

Abstract

Objective

While mixed dentition space analysis is a common practice in pediatric dentistry, digital models created using an intraoral scanner are not as widely used in clinical settings. This preliminary study used a very small sample size with one reference model and aimed to (1) compare the accuracy of mixed dentition space analysis using a digital model obtained from an optical impression with that of conventional plaster model-based analysis and (2) assess inter-examiner differences.

Results

The space required for the mandibular permanent canine and premolars and arch length discrepancy were calculated using each model. The largest significant difference between plaster- and digital model-based analyses was identified when the right arch length discrepancy was considered (-0.49 mm; 95% confidence interval: -0.95–0.03); however, the value was considered clinically insignificant. Significant inter-examiner differences were observed for six items of the plaster model; however, no such differences were observed when using the digital model. In conclusion, digital model space analysis may have the same level of accuracy as conventional plaster model analysis and likely results in smaller inter-examiner differences than plaster model analysis.

Peer Review reports

Introduction

Crowding is a common issue among children with mixed dentition. Anterior crowding is identified as the discrepancy between the interdental width of the four permanent incisors and the available space of the alveolar base [1]. Particularly, mandibular anterior crowding is frequently discovered by parents or dentists during the early stages of mixed dentition. [2]. The possible causative factors for mandibular anterior crowding in the early mixed dentition are premature loss of primary teeth attributed to dental caries or trauma, and fused primary teeth, which is associated with tooth misalignment [3, 4].

Crowding can negatively impact oral health by making optimal oral hygiene maintenance challenging, resulting in periodontal disease and esthetic concerns. Dental crowding was significantly associated with a high prevalence of gingivitis in 6–12-year-old schoolchildren [5]. According to a recent systematic review, the prevalence of dental crowding increased from primary to mixed dentition, rising from 16 to 37% [6]. Therefore, the presence of crowded mandibular incisors increases the risk of periodontal disease [7]. Moreover, dental crowding has been found to have a significant impact on the quality of life and self-esteem related to oral health [8]. This finding indicates that crowding is involved in dentofacial esthetics. Nevertheless, a recent study revealed that treating crowding in children will improve the psychological health, well-being, and body image in adulthood [3].

When considering interventions for mandibular incisor crowding in the mixed dentition, it is important to take into account the anatomical limitations of the mandibular arch, potential impact on the child’s quality of life, and amount of time required for treatment. In orthodontic treatment planning, the clinician can make decisions based on the likelihood of spontaneous alignment of the mandibular incisors in children with crowding up to 4 mm [9]. Space analysis is crucial for determining whether to implement early orthodontic intervention or merely monitor occlusal development during the mixed dentition period as it helps in selecting the most appropriate approach [10]. In addition, the analysis helps clinicians plan treatments based on current space measurements and tooth size predictions [11]. Thus, mixed dentition space analysis is essential for early diagnosis and successful treatment of developing malocclusions, which can yield long-lasting benefits in the quality of life in patients.

Space analysis involves accurately comparing the space available with that required to align the teeth. The analysis is performed by taking measurements using plaster models and a caliper; therefore, it may be influenced by the examiner’s measurement skills. Previous studies have reported the reliability of digital model analysis of permanent dentition [12,13,14]. The studies showed that most digital model-based measurements had clinically acceptable accuracy comparable with those made using a caliper to assess plaster models. A recent systematic review also reported the high accuracy of digital and alginate impression methods [15]. However, the digital model-based measurement method may affect the reproducibility of measurements [12].

Although mixed dentition space analysis is frequently performed in clinical pediatric dentistry, digital models made using an intraoral scanner are used less frequently in clinical practice. We believe it is necessary to study the usefulness of intraoral scanners and digital models to promote their use in pediatric dentistry. However, evidence on the reliability of digital model analysis in mixed dentition periods is limited, and the usefulness of digital models for space analysis in pediatric patients remains unclear [16]. Therefore, this preliminary study aimed to compare the accuracy of space analysis using a digital model with analysis using a conventional plaster model and to assess inter-examiner differences.

Methods

A mandibular mixed dentition model for pediatric dental training (PDI5004-UL-SCP-HM, Nissin Inc., Tokyo, Japan) was used as a reference. Measurements were performed using (A) the reference model, (B) a plaster model obtained from a conventional impression of the reference model made using alginate impression material, and (C) a digital model obtained from an optical impression of the reference model made using an intraoral scanner (Primscan, Dentsply Sirona K.K., Tokyo, Japan; Fig. 1).

Fig. 1
figure 1

Models used in this study (a) A mixed dentition model for pediatric dental training used as a reference model, (b) a plaster model made from an impression of the reference model using alginate impression material, and (c) a digital model obtained from an optical impression of the reference model using an intraoral scanner are shown

The mesiodistal widths of the four permanent mandibular incisors—the right lateral incisor (R2), right central incisor (R1), left central incisor (L1), and left lateral incisor (L2)—and available space for the permanent canines and premolars (AS) on both sides were measured for mixed dentition space analysis. To analyze the AS, considering the crowding of the mandibular incisors, points were marked on the dental arch by assuming the normal position of the incisors, and the distance to the mesial surface of the permanent mandibular first molar was measured. The required space for the permanent mandibular canine and premolars (RS) was calculated from the sum of the mesiodistal widths of the four incisors using the following regression formula by Ono [17] based on the Japanese population:

$$ {\text{RS}} = ({\text{R}}2 + {\text{R}}1 + {\text{L}}1 + {\text{L}}2) \times 0.548 + 8.52 + 0.56$$

The RS was subtracted from the AS to calculate both sides’ arch length discrepancy (ALD).

A licensed pediatric dentist (examiner 1) performed six reference model measurements using a digital caliper (Vernier Caliper, Matsui Seimitsu Co., Niigata, Japan), with the average of the measurements being used as the reference value. The same examiner also performed measurements on plaster and digital models. Six measurements each on plaster and digital models were performed at 1-h intervals on the same day using a caliper and dedicated CEREC Ortho SW2.0 (Dentsply Sirona K.K., Tokyo, Japan) software, respectively. A third researcher read all caliper values measured by the examiner, and the examiner performed the next measurement without verifying the previous one. Therefore, the examiner was blinded to the measurements. The accuracy of model analysis was ensured by comparing the average values of the six measurement types determined using plaster, digital, and reference models. This was a preliminary study with a very small sample size. Hence, hypothesis testing/p-values were omitted. The mean differences between the three models were calculated with 95% confidence intervals (CIs).

Next, another pediatric dentist (examiner 2) performed measurements of plaster and digital models using the aforementioned methods, allowing for inter-examiner comparisons (examiner 1 vs. examiner 2). The two examiners reviewed each measurement method of the plaster and digital model-based mixed dentition space analysis together before taking the measurement. The mean differences with 95% CIs were calculated to compare plaster and digital model measurements taken by each of the examiners. When interpreting the CI, values of zero indicate that no difference was indicated, and nonzero values indicate differences between compared items.

Results

Table 1 presents each model’s mean (standard deviation) measurements and the mean difference (95% CI) between the two models. Comparisons of the mean plaster and digital model measurements with the reference value obtained by examiner 1 revealed significant differences for six items. Table 2 shows the mean measurements obtained by each examiner and mean inter-examiner differences for each model. Significant inter-examiner differences were observed for six items measured using the plaster model; however, no inter-examiner differences were observed for the digital model. Significant inter-examiner differences for five items were observed when plaster and digital model differences were considered.

Table 1 Comparison of measurements determined using three models
Table 2 Between-examiner comparison of mandibular measurements of plaster and digital models

Discussion

In this study, we compared the accuracy of the mixed dentition space analysis using a digital model obtained from an optical impression with that of the conventional plaster model-based analysis. A digital model was obtained from an optical impression made using an intraoral scanner. Similar to other three-dimensional scanners, an intraoral scanner is a device that captures direct optical impressions by projecting a light source onto the dental arch [18]. Optical impressions have several advantages, including enhanced comfort for patients, simplified clinical procedures, reduced storage requirement, real-time visualization, true color representation, and better communication with patients [15, 18]. Meanwhile, the disadvantages of optical impressions include the learning curve for adopting intraoral scanners and purchasing and managing costs.

A plaster model was obtained from a conventional impression using alginate impression material. In clinical settings, alginate impression material is placed on a tray, which is held in the patient’s mouth for several minutes till setting of the material. Once the impression has been taken, the tray is disinfected and then filled with hard plaster to create a plaster model. In this conventional impression taking procedure, certain problems may arise, including the presence of air bubbles, the rupture of the impression material, inaccurate impression tray dimensions, excessive or insufficient amount of impression material, inadequate adhesion of the impression to the tray, and impression material distortion owing to the disinfection procedure [12]. Further, the conventional impression may induce a gag reflex in some patients. However, the advantages of conventional impression taking include low cost, ease of handling, short placement time, and simple instrumentation and impression taking methods [19].

Kaihara et al. [20] compared tooth size, arch width, and length values determined in primary dentition using digital models with those determined using plaster models. The authors concluded that digital model-based analyses of primary dentition have high accuracy levels. In this mixed dentition study, comparing the plaster- and digital model-based measurements with those of the reference model revealed significant differences in six items. According to the literature, a difference in tooth size of > 0.3 mm is considered clinically relevant [21]. However, our results showed differences in six items ranging from 0.06 to 0.18 mm, indicating no clinically significant differences in accuracy. In contrast, a comparison of the measurements of the plaster model with those of the digital model revealed significant differences in the three items, with values ranging from 0.11 to 0.49 mm. Leifert et al. [22] compared the efficacy of plaster and digital models for space analysis of crowded permanent dentitions with Class I malocclusions. They concluded that the statistical difference in arch length measurement was not clinically significant (< 0.50 mm) [22]. In our study, the maximum mean difference between space analysis findings (ALD, right) of plaster and digital models was 0.49 mm. Although the method of analysis differed from that of previous reports, the values obtained in this study were similar to those of prior studies and may be regarded as clinically insignificant. Therefore, the digital model’s optical impression and analytical accuracies indicated that it was clinically useful.

Significant inter-examiner differences were identified for six items when the plaster model was measured. In this study, a model with anterior crowding was selected. Before taking the measurements, the examiners reviewed the mixed dentition space analysis measurements using the plaster and digital models. Nevertheless, the difficulty associated with measuring crowding of the mandibular incisors with a caliper and the more complex measurements required for space analysis after correcting incisor crowding may have been causes of between-examiner measurement differences. This finding suggests that while analyzing the plaster model, it is necessary to reduce inter-examiner differences via careful calibration, such as establishing measurement sites and a uniform method of caliper use.

In contrast, no significant differences were observed when the items were measured using the mixed dentition digital model with anterior crowding, wherein the measurements were performed using dedicated software. Kamimura et al. [23] investigated the inter-examiner reproducibility of digital and conventional impression techniques in permanent dentition. They observed that the digital impression technique has superior reproducibility compared with the conventional technique. Furthermore, they suggested that this advantage is independent of the examiner’s clinical experience or the patient’s oral health status, these findings are consistent with those of this study.

Significant inter-examiner differences between the plaster and digital models were observed for five items. Since the RS measurements of the two examiners did not significantly differ, inter-examiner differences were attributed to plaster model AS measurement differences. A recently published study indicated that digital measurement methods that do not rely on manual measurement with a caliper have improved accuracy [24]. Therefore, using measurement software for digital model analysis may facilitate uniform and accurate analysis, thereby minimizing inter-examiner differences. In addition, optical impressions are preferred over conventional impressions in children since they allow for better control of the gag reflex [25, 26]. Collecting digital data allows for the analysis of changes in oral condition progression without the need for storing plaster models. Hence, intraoral scanners are expected to be useful in clinical pediatric dentistry.

We believe that our preliminary study makes a significant contribution to the literature because limited studies have investigated the reliability of mixed dentition space analysis using a digital model fabricated using an intraoral scanner. In conclusion, this type of analysis using a digital mixed dentition model obtained using an optical impression may have the same level of accuracy as conventional plaster model analysis. Inter-examiner differences may be smaller in the digital model than in the plaster model-based analysis. However, more comprehensive future studies with actual pediatric patients are required to substantiate the significant results of this study. Further studies comparing the results of mixed dentition space analyses using plaster and digital models of pediatric patients are warranted to better determine their clinical usefulness.

Limitations

This preliminary study had some limitations. First, the most serious weakness of this study was the very small sample size, with only one reference model. Therefore, it is essential to further increase the sample size to generalize this study’s results. Second, the models considered were not prepared based on the oral cavity of an actual pediatric patient. Therefore, the impact of the oral environment and patient behavior on the fabricated models and the related effects on the accuracy of the mixed dentition space analysis were not clarified. Lastly, we performed linear but not three-dimensional measurements. Three-dimensional measurement is easier on digital models than on plaster models. Therefore, future studies should consider three-dimensional assessments to more completely validate the accuracy of mixed dentition space analyses using digital models.

Data availability

The datasets generated and analyzed during the current study are available from the corresponding authors upon reasonable request.

Abbreviations

AS:

available space for canine and premolars

ALD:

arch length discrepancy

CI:

confidence interval

L1:

mandibular left central incisor

L2:

mandibular left lateral incisor

R1:

mandibular right central incisor

R2:

mandibular right lateral incisor

RS:

required space for canine and premolars

References

  1. Türkkahraman H, Sayin MO. Relationship between mandibular anterior crowding and lateral dentofacial morphology in the early mixed dentition. Angle Orthod. 2004;74:759–64.

    PubMed  Google Scholar 

  2. Ohno Y, Fujita Y, Ohno K, Maki K. Relationship between oral function and mandibular anterior crowding in early mixed dentition. Clin Exp Dent Res. 2020;6:529–36.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Turner S, Harrison JE, Sharif FN, Owens D, Millett DT. Orthodontic treatment for crowded teeth in children. Cochrane Database Syst Rev. 2021;12:Cd003453.

    PubMed  Google Scholar 

  4. Bernardi S, Bianchi S, Bernardi G, Tchorz JP, Attin T, Hellwig E, et al. Clinical management of fusion in primary mandibular incisors: a systematic literature review. Acta Odontol Scand. 2020;78:417–24.

    Article  PubMed  Google Scholar 

  5. Liu X, Xu J, Li S, Wang X, Liu J, Li X. The prevalence of gingivitis and related risk factors in schoolchildren aged 6–12 years old. BMC Oral Health. 2022;22:623.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Lombardo G, Vena F, Negri P, Pagano S, Barilotti C, Paglia L, et al. Worldwide prevalence of malocclusion in the different stages of dentition: a systematic review and meta-analysis. Eur J Paediatr Dent. 2020;21:115–22.

    PubMed  CAS  Google Scholar 

  7. Alsulaiman AA, Kaye E, Jones J, Cabral H, Leone C, Will L, et al. Incisor malalignment and the risk of periodontal Disease progression. Am J Orthod Dentofacial Orthop. 2018;153:512–22.

    Article  PubMed  Google Scholar 

  8. Jung MH. An evaluation of self-esteem and quality of life in orthodontic patients: effects of crowding and protrusion. Angle Orthod. 2015;85:812–9.

    Article  PubMed  Google Scholar 

  9. Dos Santos CCO, da Rosa Moreira Bastos RT, Bellini-Pereira SA, Garib D, Normando D. Spontaneous changes in mandibular incisor crowding from mixed to permanent dentition: a systematic review. Prog Orthod. 2023;24:15.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Chong SY, Aung LM, Pan YH, Chang WJ, Tsai CY. Equation for tooth size prediction from mixed dentition analysis for Taiwanese population: a pilot study. Int J Environ Res Public Health. 2021;18:6356.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Al-Abdallah M, Sandler J, O’Brien K. Is the Royal London Space Analysis reliable and does it influence orthodontic treatment decisions? Eur J Orthod. 2008;30:503–7.

    Article  PubMed  CAS  Google Scholar 

  12. Camardella LT, Breuning H, De Vasconcellos Vilella O. Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner. J Orofac Orthop. 2017;78:211–20.

    Article  PubMed  Google Scholar 

  13. Park SH, Byun SH, Oh SH, Lee HL, Kim JW, Yang BE, et al. Evaluation of the reliability, reproducibility and validity of digital orthodontic measurements based on various digital models among young patients. J Clin Med. 2020;9:2728.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Zhang F, Suh KJ, Lee KM. Validity of intraoral scans compared with plaster models: an in-vivo comparison of dental measurements and 3D surface analysis. PLoS ONE. 2016;11:e0157713.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Kong L, Li Y, Liu Z. Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies. Clin Oral Investig. 2022;26:5625–42.

    Article  PubMed  Google Scholar 

  16. Goracci C, Franchi L, Vichi A, Ferrari M. Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence. Eur J Orthod. 2016;38:422–8.

    Article  PubMed  Google Scholar 

  17. Ono H. Correlation between mesiodistal width of the deciduous teeth and that of permanent teeth in maxillary and mandibular dentition. J Stomatological Society Japan. 1960;27:221–34. (in Japanese).

    Article  Google Scholar 

  18. Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health. 2017;17:149.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Cervino G, Fiorillo L, Herford AS, Laino L, Troiano G, Amoroso G, et al. Alginate materials and dental impression technique: a current state of the art and application to dental practice. Mar Drugs. 2018;17:18.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Kaihara Y, Katayama A, Ono K, Kurose M, Toma K, Amano H, et al. Comparative analyses of paediatric dental measurements using plaster and three-dimensional digital models. Eur J Paediatr Dent. 2014;15:137–42.

    PubMed  CAS  Google Scholar 

  21. Fleming P, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res. 2011;14:1–16.

    Article  PubMed  CAS  Google Scholar 

  22. Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop. 2009;136:16e1–4.

    Article  Google Scholar 

  23. Kamimura E, Tanaka S, Takaba M, Tachi K, Baba K. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques. PLoS ONE. 2017;12:e0179188.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Rolfsen CC, Fidel PL, Wen Z, Chapple A, Ahluwalia JP, DiVittorio A, et al. Direct comparison between intraoral scanning and alginate impressions for pediatric patients: an in vitro study. J Dent Child (Chic). 2023;90:17–21.

    PubMed  Google Scholar 

  25. Yilmaz H, Aydin MN. Digital versus conventional impression method in children: comfort, preference and time. Int J Paediatr Dent. 2019;29:728–35.

    Article  PubMed  Google Scholar 

  26. Glisic O, Hoejbjerre L, Sonnesen L. A comparison of patient experience, chair-side time, accuracy of dental arch measurements and costs of acquisition of dental models. Angle Orthod. 2019;89:868–75.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We thank Editage (https://www.editage.jp/) for editing and reviewing this manuscript for the English language.

Funding

This study was supported by the Nippon Dental University, School of Life Dentistry in Tokyo, Japan and the Japan Society for the Promotions of Science (Grant Number 20K10257).

Author information

Authors and Affiliations

Authors

Contributions

HK and AO designed the study and performed the research. ST, TK, and AS provided assistance and advice on the optical impressions made using the intraoral scanner. ST, TK, and AS analyzed and interpreted the data. HK and AO wrote the manuscript. All the authors contributed to the editorial changes in the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Hiroyuki Karibe.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Okamoto, A., Karibe, H., Tanaka, S. et al. Reliability of mixed dentition space analysis using a digital model obtained from an optical impression: a preliminary study. BMC Res Notes 17, 12 (2024). https://doi.org/10.1186/s13104-023-06678-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13104-023-06678-4

Keywords